DT1000 Series Standalone Communication Inverter (24Vdc/48Vdc)

Standard 19-inch rack mount | Pure sine wave output | 5-channel dry contact monitoring | Designed specifically for communication base stations

  1. 📏 19-inch 2U rack mount
  2. 📊 Pure sine wave output
  3. 🔌 5 dry contact points (fault monitoring)
  4. ⏱️ Switching time ≤5ms
  • DC Input Voltage: 48Vdc (24Vdc optional)
  • AC Output Voltage: 110/220/230Vac
  • Power Range: 1KVA ~ 10KVA
  • Output Frequency: 50/60Hz (±0.1%)
  • Inverter Efficiency: ≥85%
  • Operating Temperature: -40℃ ~ +55℃
24V48V DT1000 Series Standalone Communication Inverter (1)
24V48V DT1000 Series Standalone Communication Inverter (2)
24V48V DT1000 Series Standalone Communication Inverter (4)
24V48V DT1000 Series Standalone Communication Inverter (3)
INPUT
AC Input Voltage 83-135A
Battery Input Voltage 24Vdc
Battery Voltage Range 22-28Vdc
Cooling Fan Cool(Temp.Control Speed According to the output capacity)
DC Input Current 125AMax
Output Frequency 50Hz/60Hz±1%
PF 0.8
OUTPUT
Output Capacity 1000VA/ 2000VA/ 3000VA
Rated Output Capacity 800W/ 1600W/ 2400W
Rated output Voltage 110VAC (Inverter Mode )
Rated Output Current 7.2A/14.4A/21.8A
Output Voltage Range 110Vac(Tolerance ±1.5% @Inverter Mode)
Output Efficiency ≥85% (Inverter Mode)
Output Frequency 50Hz/60Hz
Frequency Range 43~67Hz
Output Wave Pure sine wave
THD ≤3% (Line Load)
Switch Time (By pass to Inverter mode) ≤6ms (With Load)
PROTECTIVE FEATURE
AC Under Voltage Switch Protection ≤88VAC (Backlash voltage≥5Vac)
AC over Voltage Switch protection ≥132VAC
Over-Temperature Yes (Auto Switch)
Battery under voltage protection point ≤40VDC
Battery Low-voltage alarm 43VDC±0.5
Battery overvoltage protection point ≥60VDC
Battery overvoltage recovery point ≤57VDC
Output Over Current Protection
Over Load Capacity Continue working 60s @100%<load<120%
Over Load Capacity Continue working 10s @ 121%<Load<150%
Over Temp. Protection Yes
short circuit Protection Yes (Don’t test under AC Connect)
Reverse connection protection Yes
Output OVP ≥132VAC(Inverter Mode)
Output low voltage alarm ≤88VAC (Inveter Mode)
SAFETY AND EMC
Dielectric strength(AC-Chassis) 3500Vdc/10mA//1min .No flash over, no breakdown, no arc (Only AC Input priority)
Dielectric strength(DC-Chassis) 750Vdc/10mA/1min. No flash over, no breakdown
LVD EN 60950-1
EMC/EMI EN 61000-6-3; EN 61000-6-1 ;IEC 61000-6-2 and IEC 61000-6-4
ROHS IEC62321-4, IEC 62321-5,IEC 62321-6,IEC 62321-7,IEC 62321-8
ENVIRONMENT TEST PERFORMANCE
Ambient Temp. -20~ +50℃
High temperature operation 50±2℃ (rated load 24H)
Low temperature operation -20±2℃ (rated load 24H)
High temperature storage 80±2 ℃,24H
Low temperature storage -40±2℃,24H
Humidity 0~90%,No moisture condensation
Operating Altitude (m) Altitude Full power up to 2000m.derating -2% / 100m, max altitude 5000m
COMMUNICATION
Rs232 & Rs485 Yes
SNMP Optional
Dry Contact 5 group
LCD DISPLAY
LCD Status Input and output Voltage, Frequency ,Output Current,Temp., Load Rate,LOGO etc.
Inverter Status Normal Mains, Normal Inverter, Battery Under-voltage and output overload etc.
MEASUREMENT
Size W*D*H(mm) 482mm*370mm*88mm (2RU)
Weight 11KG
Scroll to Top