DT2000 Series Parallel Power Inverters (110 VDC / 220 VDC)

N+1 Parallel Redundancy Design | Masterless Parallel Technology | Up to 8 Modules in Parallel | Real-time Data Acquisition | Suitable for High-Power Applications

  1. 🔗 N+1 Parallel Redundancy
  2. 👑 Masterless Parallel Technology
  3. 🧩 Up to 8 Modules in Parallel
  4. 📈 Real-time Data Acquisition
  5. ⚡ 110V/220V High-Voltage DC Input
  • DC Input Voltage: 110 Vdc / 220 Vdc
  • AC Output Voltage: 220 Vac
  • Module Power Range: 3 kVA – 10 kVA
  • Maximum System Cabinet Power: 80 kVA
  • Output Frequency: 50 Hz (±0.1%)
  • Inversion Efficiency: ≥90%
  • Parallel Current Imbalance: <3%
24V48V DT1000 Series Standalone Communication Inverter (3)
FeatureDescription
N+1 Parallel Redundancy DesignSupports parallel connection of multiple modules; failure of any module does not affect system power supply, significantly improving system reliability
Masterless Parallel TechnologyNo need to set master or slave modules; any module can operate independently, with automatic current sharing during parallel operation, simplifying installation and maintenance
32-bit Digital DSP ControlUses high-speed digital signal processor combined with high-frequency SPWM technology for high control precision and fast dynamic response
Up to 8 Modules in ParallelA single system cabinet can support up to 8 modules in parallel, offering flexible power expansion with a maximum capacity of 80KVA
Real-time Data AcquisitionMonitors parameters such as input voltage, output voltage, current, frequency, and temperature in real time, facilitating operation and maintenance management
Remote CommunicationSupports RS485 communication, with optional SNMP card for easy integration into power system monitoring platforms
Configurable Transfer PriorityAllows flexible setting of inverter priority or bypass priority based on application requirements, adapting to different power supply scenarios
Compact 2U DesignEach module is only 2U in height, offering high power density and saving cabinet space
Product formRated power1KVA2KVA3KVA5KVA6KVA
Dimensions (Width×height×depth)(mm)19"2U19"2U
490×88×385490×88×392
Input parameterDC input voltage110VDC
AC input Current4.55A9.1A13.6A22.7A27.3A
DC input range92~142VDC
Bypass input range176~264VAC
Bypass switching timeElectronic type<5ms(external)
Mechanical type<20ms
Ac outputRated output voltage220VAC
Rated output frequency50Hz
Load regulation<1%
Frequency accuracy<0.1%
peak factor3:01
Waveform distortionResistance full load<3%,nonlinear full load<5%
Dynamic responseVoltage transient range<3%,transient response recovery time≤60ms(load from 0 to 100)
Parallel uneven flow<3% rated current RMS
Overload capacityLoad current <105%, continuous work
Load current 105~125%, continuous work 10min shutdown
Load current 125~150%,continuous work after 1min shutdown
Load current>150%,after 20ms shutdown
Protection functionInput connection protection, input under voltage and over-voltage protection, output overload protection, output short circuit protection, over temperature protection
CommunicationCommunication interfaceRS485
Work environmentInsulation strength2KVac,1min
Noise (1 m)<45dB
Operating ambient temperature-10~50℃
Transport and storage temperature-40~70℃
Relative humidity0~90%, no condensation
Relative altitude (M)≤3000m,1500~3000m, 1% decrease in output for every 100 m increase
Large Substation🏭Provides N+1 redundant power supply for AC loads within the station, ensuring reliable operation of relay protection and monitoring systems
Power Plant Complex Building⚡Modular design allows on-demand expansion to meet the power supply requirements of various AC loads in the power plant
Data Center🖥️Parallel redundancy design, combined with STS, enables a high-availability power architecture
Large Industrial and Mining Enterprises🏗️Provides highly reliable inverter power for production line control systems and critical equipment
Rail Transit🚄Suitable for high-power AC power supply scenarios in substations along subways and railway lines
What is the difference between the DT2000 and the DT1500?

The DT2000 focuses on high-voltage DC inputs (110/220V) for power systems; it employs masterless parallel technology and supports the parallel operation of up to 8 modules. The DT1500 covers both telecommunications and power system voltage ranges; it features a modular, hot-swappable design and supports the parallel operation of up to 4 modules.

A single system cabinet supports the parallel operation of up to 8 modules, with a total power output reaching up to 80 kVA. For higher power requirements, multi-cabinet parallel solutions can be customized.

Traditional parallel systems require the designation of a “master” unit and “slave” units; if the master unit fails, the entire system may be compromised. With masterless technology, all modules operate on an equal footing—any module can function independently, and current sharing is automatically balanced during parallel operation, resulting in significantly higher reliability.

Yes. The standard cabinet sizes are 42U, 45U, and 48U; however, the power distribution configuration, IP protection rating, and physical dimensions can all be customized to meet specific project requirements.

For a single module, the transfer time from bypass mode to inverter mode is ≤8 ms. When the system cabinet is equipped with a built-in Static Transfer Switch (STS), the switching time is ≤4 ms, thereby meeting the stringent switching-time requirements of critical loads.

The modules come standard with an RS485 interface, and the system cabinet offers an optional SNMP card; this enables integration with power system monitoring platforms, facilitating real-time remote monitoring.