(110Vdc/220Vdc) DT1000 Series Standalone Communication Inverter

Dedicated High-Voltage DC Input for Power Systems | Pure Sine Wave Output | 5-Channel Dry Contact Monitoring | High-Frequency PWM/SPWM Control Technology

  1. ⚡ 110V/220V High-Voltage DC Input
  2. 📏 19-inch 2U Rack-Mountable
  3. 📊 Pure Sine Wave Output
  4. 🔌 5 Dry Contact Channels (Fault Monitoring)
  5. 🎛️ High-Frequency PWM/SPWM Control

 

  • DC Input Voltage: 110 VDC / 220 VDC
  • AC Output Voltage: 110 / 220 / 230 VAC
  • Power Range: 1 kVA – 10 kVA
  • Output Frequency: 50 / 60 Hz (±0.1%)
  • Inversion Efficiency: ≥85%
  • Operating Temperature: -25°C – +50°C
24V48V DT1000 Series Standalone Communication Inverter (2)
24V48V DT1000 Series Standalone Communication Inverter (4)
24V48V DT1000 Series Standalone Communication Inverter (3)
FeatureDescription
Dedicated Power System DesignDesigned for 110V/220V DC panels in substations and power plants, providing reliable power to AC loads
Standard 19-inch Rack Mount2RU height design, can be installed in standard power equipment cabinets, saving space
Pure Sine Wave OutputHigh output waveform quality, suitable for sensitive loads such as relay protection and monitoring instruments
5 Dry Contact Monitoring AlarmsDC input fault, AC input fault, overload signal, bypass information, output fault, real-time reporting
High-Frequency PWM/SPWM ControlUses high-frequency pulse width modulation technology for high control precision and fast dynamic response
Real-time Status MonitoringLCD display provides real-time information on input voltage, output voltage, frequency, output current, temperature, operating mode, etc.
Audible and Visual AlarmTriggers audible and visual alarms upon fault, enabling on-site personnel to quickly locate issues
Multi-battery CompatibilitySupports lithium batteries, lead-acid batteries, gel batteries, and nickel-cadmium batteries
INPUT
AC Input Voltage170-270A
Battery Input Voltage48Vdc
Battery Voltage Range104-131Vdc
CoolingFan Cool (Temp.Control Speed According to the output capacity)
DC Input Current90AMax
Output Frequency50Hz/60Hz±1%
PF0.8
OUTPUT
Output Capacity1000VA/ 2000VA/ 3000VA/ 4000VA/ 5000VA/ 6000VA/
8000VA/ 10000VA
Rated Output Capacity800W/ 1600W/ 2400W/ 3200W/ 4000W/ 4800W/6400W/
7000W
Rated output Voltage220VAC (Inverter Mode )
Rated Output Current3.6A/ 7.3A/ 11A/ 14.5A/ 18.2A/ 21.8A/ 29A/ 36.3A
Output Voltage Range220Vac(Tolerance ±1.5% @Inverter Mode)
Output Efficiency≥85% (Inverter Mode)
Output Frequency50Hz/60Hz
Frequency Range43~67Hz
Output WavePure sine wave
THD≤3% (Line Load)
Switch Time (By pass to Inverter mode)≤6ms (With Load)
PROTECTIVE FEATURE
AC Under Voltage Switch Protection≤176VAC (Backlash voltage≥5Vac)
AC over Voltage Switch protection≥264VAC
Over-TemperatureYes (Auto Switch)
Battery under voltage protection point≤20VDC
Battery Low-voltage alarm22VDC±0.5
Battery overvoltage protection point≥103VDC
Battery overvoltage recovery point≤130VDC
Output Over Current Protection
Over Load CapacityContinue working 60s @100%<load<120%
Over Load CapacityContinue working 10s @ 121%<Load<150%
Over Temp. ProtectionYes
short circuit ProtectionYes (Don’t test under AC Connect)
Reverse connection protectionYes
Output OVP≥264VAC(Inverter Mode)
Output low voltage alarm≤176VAC (Inveter Mode)
SAFETY AND EMC
Dielectric strength(AC-Chassis)3500Vdc/10mA//1min .No flash over, no breakdown, no arc (Only AC Input priority)
Dielectric strength(DC-Chassis)750Vdc/10mA/1min. No flash over, no breakdown
LVDEN 60950-1
EMC/EMIEN 61000-6-3; EN 61000-6-1 ;IEC 61000-6-2 and IEC 61000-6-4
ROHSIEC62321-4, IEC 62321-5,IEC 62321-6,IEC 62321-7,IEC 62321-8
ENVIRONMENT TEST PERFORMANCE
Ambient Temp.-20~ +50℃
High temperature operation50±2℃ (rated load 24H)
Low temperature operation-20±2℃ (rated load 24H)
High temperature storage80±2 ℃,24H
Low temperature storage-40±2℃,24H
Humidity0~90%,No moisture condensation
Operating Altitude (m)Altitude Full power up to 2000m.derating -2% / 100m, max altitude 5000m
COMMUNICATION
Rs232 & Rs485Yes
SNMPOptional
Dry Contact5 group
LCD DISPLAY
LCD StatusInput and output Voltage, Frequency ,Output Current,Temp., Load Rate,LOGO etc.
Inverter StatusNormal Mains, Normal Inverter, Battery Under-voltage and output overload etc.
MEASUREMENT
Size W*D*H(mm)482mm*347mm*88mm (1-4KVA)
482mm*430mm*88mm (5-6KVA)
482mm*470mm*176mm (8-10KVA)
Weight11KG-30KG
Substation🏭Inverts the 110V/220V DC panel power within the station into AC to supply monitoring, protection, and communication equipment
Power Plant⚡Provides reliable inverter power for AC instruments, lighting, and control equipment in the power plant
Railway Power System🚄Suitable for substations along railway lines, supplying AC power to signaling and communication equipment
Industrial and Mining Enterprise Distribution Room🏗️Converts the enterprise's high-voltage DC operating power into AC for use by control equipment
What is the difference between the Power-type and Communication-type DT1000 models?

The primary difference lies in the input voltage. The Power-type model supports high-voltage DC inputs (110V/220V), making it suitable for use with DC power distribution panels in power systems; the Communication-type model supports low-voltage DC inputs (24V/48V), making it suitable for use with battery banks in communication base stations.

The standard product models are designed for 110 Vdc and 220 Vdc inputs; for other voltage levels, please contact us regarding custom solutions.

No, it does not. The DT1000 series features a standalone design; if parallel redundancy functionality is required, we recommend selecting the DT2000 parallel series instead.

The product comes standard with RS232 and RS485 interfaces, and an optional SNMP card is available to enable integration with power system monitoring platforms.

The transfer time from bypass mode to inverter mode is ≤5 ms, meeting the switching time requirements of power systems.

The standard operating altitude is ≤2000 m. For higher altitudes, derating is required; please contact us for a specific solution tailored to your needs.